TriLambdaXRM-30

Nano X-ray Microscope
Spatial resolution to 35nm
Up to 3 X-ray Energies in Single System

Key Advantages:

Nanoscale 35nm Spatial Resolution

The TriLambda nanoXRM achieves over an order of magnitude in superior resolution compared to lensless x-ray microscopes such as the PrismaXRM, which do not use x-ray optics. Such resolution is achieved through the use of Sigray’s proprietary double paraboloidal x-ray optics and diffractive focusing zone plate optics. PrismaXRM and TriLambdaXRM provide natural multi-scale complements to each other; PrismaXRM provides submicron imaging of larger samples, while the TriLambda provides 35-100nm resolution imaging of smaller samples.

Outstanding 35-50nm resolutions can be achieved for x-ray energies ranging from 2.7 keV to 8.04 keV.
Three X-ray Wavelengths (Tri-Lamba) in a Single System

Up to three x-ray energies are included in the TriLambda system, providing optimal illumination for the wide range of samples seen in a busy central laboratory. X-ray contrast varies significantly for each x-ray energy, impacting both the time to acquire data and more importantly, the visibility of structures. For example, 5.4 keV is optimal for geological samples (SiO2) but poor for samples with metal in them. For polymers and cells, soft x-ray energies (2.7 keV) provide profound advantages over 8 keV.

Dual Energy (Dual Contrast)

Interpreting contrast measurements and CT numbers can be a difficult task when only a single X-ray energy is used for imaging. This is due to the presence of sub-resolution features, such as nanoporosity or nano-scale alloying elements that change the absorption of a sample and lead to errors in image segmentation and inaccurate quantification of the atomic number of a material. By imaging at two different x-ray illumination energies (dual energy), TriLambda removes such errors.

3D surface rendering of segmented Fe NPs (orange) in relation to the graphite clusters acquired with dual contrast

System Features

Patented Multi-Target Ultrahigh Brightness X-ray Source

TriLambda’s x-ray source features a patented design in which multiple target materials are in optimal thermal contact with diamond, which has excellent thermal conductivity properties. The rapid cooling of diamond enables higher power loading on the x-ray source to produce an intense beams of x-rays. This thermal benefit enables more materials to be used as x-ray source target materials, each of which produce strong characteristic x-rays of a specific energy. Up to 3 target materials can be customized for the TriLambda-30 source, allowing software selection of the optimal spectra for your sample.

Software: GigaRecon Tomography & Sigray3D Acquisition

GigaRecon | Tomographic reconstruction software that pairs the fastest reconstruction times with an unmatched suite of features for achieving the best result every time. Reconstruction speeds of <45 seconds are achieved for 2048 x 2048 x 2200 datasets. GiagRecon provides the fastest iterative tomography reconstruction on the market, enabling high quality image reconstruction with 5X shorter data collection time, substantially accelerating tomography imaging time over conventional FDK reconstruction.

Sigray3D | Intuitive Acquisition
  • Easy, intuitive software gets your team up and running in no time
  • Click to align the sample and start measuring in seconds
  • AI powered AutoPilot suggests the optimal settings for each sample
  • Queue up to 20 samples with the automated Sample Handling Robot (SHR)
GigaRecon provides high quality data with far fewer views required
Sigray3D features an intuitive GUI for acquiring and measuring data

Applications

Batteries

The microstructure of electrodes are increasingly of interest because it is now recognized that damage incurred and agglomeration of particles from charging limits the long-term reliability and lifetime. TriLambdaXRM provides the resolution needed to see these changes – and because of the non-destructive nature of x-rays, can be used to observe such changes over time or in-operando.

Polymers and Biological Samples

A key feature of the TriLambdaXRM is its ability to resolve polymers and biological samples at the nanoscale. Such samples are extremely challenging to image using electron-based techniques due to charging. Using a low “tender” x-ray energy to illuminate the sample at 2.7 keV, TriLambda is able to provide 3D nanoscale biological and polymeric tomographies non-destructively.


Technical Specifications of the TriLambda-30

 ParameterSpecification
OverallSpatial ResolutionMinimum 35nm spatial resolution at 2,7 keV
SourceType(s)Patented multi-target reflection source
Voltage20-50 kVp
Target(s)Up to 3 targets.
Si, Cr, Fe, Cu
ModesResolution and FOV Settings3 high resolution modes and 1 LFOV mode
LFOV Mode120nm resolution | 65nm voxel
65 μm FOV | 60 μm diameter optimal
OpticsCondensers3 sets of Sigray Double Paraboloidal x-ray optics matched to zone plates
Focusing ObjectiveFresnel diffraction zone plates
Phase RingZernike phase shift ring
SoftwareCommand and ControlSigray 3D with Intuitive interface
ReconstructionGigaRecon - fastest commercial CBCT reconstruction software
Linux WorkstationInterface is on a Windows workstation, while a separate robust Linux workstation controls the system. Advantageous for reliable 24-7 operation.
EPICSOpen-source software controls for maximum flexibility
DimensionsFootprint2.3m L x 1.3m W x 1.5m H

Downloads

Please contact us through the form below if you need a brochure.


Contact Us

Interested in how the Sigray TriLambdaXRM™ will help your particular application?
For a quotation and to inquire about a demonstration of the system on your particular research interests, please fill out the following inquiry form and we will get back to you within 1-2 business days.